Energy Saving Design
●According to environment and load capacity, auto adjustment to achieve the optimal heating mode and reduce energy consumption.
●New synthetic silica gel seal provides exceptional sealing with heat loss prevention and 25% energy saving.
Internal Circulation System
●Turbine suction fan and plates with heat dissipating holes, give higher ventilation and better temperature uniformity.
●Back suction and bottom vertical supply air circulation system.
Humanized Design
●LCD display of real-time parameters, and menu setting of temperature, illumination and time.
●Detachable and height-adjustable plates with min height of 30mm
●Slide-way bayonet prevents the plates tilt and dislocation.
●Radiable heating ensures temperature uniformity.
●Large arc angle, easy to clean and maintain.
●Display of "END" with buzz reminder.
●Power off memory
●℃/℉convertible
●Stackable
Safety System
●Limited temperature alarm system: auto-stop if limited temperature exceeds and auto audible and visual alarm if alarm-temperature exceeds.
●Electric leakage protection device ensures the safety of the operator and other equipment in the laboratory.
●Self diagnostic function: display fault information and facilitate troubleshooting.
Model | GOV30FA GOV30FB | GOV70FA GOV70FB | GOV130FA GOV130FB | GOV220FA GOV220FB | GOV420FA GOV420FB | GOV620FA GOV620FB | GOV960FA GOV960FB |
Volume (L/cu.ft.) | 30/1.06 | 70/2.47 | 130/4.6 | 220/7.77 | 420/14.83 | 620/21.9 | 960/33.9 |
Plate Qty (Height Adjustable) | 2 | 2 | 2 | 2 | 3 | 4 | 4 |
Load Capacity/Plate | 10kg | ||||||
Chamber Size (mm) | 340*325*290 | 400*357*470 | 450*557*520 | 500*615*720 | 600*550*1300 | 800*600*1300 | 1000*600*1600 |
Outer Size (mm) | 490*520*690 | 540*550*870 | 600*740*920 | 650*800*1130 | 750*730*1700 | 950*780*1720 | 1140*800*2150 |
Package Size (mm) | 620*630*830 | 670*660*1040 | 730*860*1080 | 780*920*1270 | 870*860*1830 | 1080*910*1880 | 910*1260*2200 |
Net Weight/Gross Weight (kg) | 40/55 | 55/75 | 70/85 | 85/110 | 120/145 | 145/170 | 195/230 |
CBM | 0.33 | 0.46 | 0.68 | 0.92 | 1.37 | 1.85 | 2.53 |
Performance | |||||||
Temperature Control Range | RT +10~250℃ (GOV-FA Series) RT +10~300℃ (GOV-FB Series) | ||||||
Temperature Resolution | ±0.1℃ | ||||||
Temperature Fluctuation | ±0.5℃ | ||||||
Ambient Temperature | 5℃~40℃ | ||||||
Timming Range | 1~9999min | ||||||
Control | |||||||
Display | LCD Display | ||||||
Controller | Microprocessor | ||||||
Sensor | PID | ||||||
Heating Pipe | Stainless steel | ||||||
Construction | |||||||
Outer Material | Laser-cutting cold-rolled steel with anti-static spraying. | ||||||
Chamber Material | Corrosion-resistant brushed stainless steel | ||||||
Plate | One-time formed 304 stainless steel entire plate, no welding spot; Load-bearing beam at the bottom, gives strong bearing capacity. | ||||||
Insulation | High quality aluminum silicate flutter cotton | ||||||
Observation Window | Double-layer toughened glass window with rubber ring | ||||||
Electrical and Noise Level | |||||||
Power Supply | 220V/50HZ | 380V | 380V | 380V | |||
Power Consumption | 550/600W | 1050/1250W | 1500/1700W | 2100/2500W | 4000/4500W | 4500/5000W | 6000/6500W |
Power Code | 0.75² | 1² | 1.5² | 1.5²/16A | Separate wiring | Separate wiring | Separate wiring |
Standard | Electric leakage protection | ||||||
Options | |||||||
1.Φ 25mm/Φ 50mm/Φ 80mm test holes | |||||||
2.Multi-segment programmable controller | |||||||
3.Independent temperature limiting controller | |||||||
4.USB Port OR Printer OR RS232 OR RS485 and communication software |