-86℃ Ultra-low Temperature Freezer
Targeted Refrigeration • Fast Refrigeration
Energy-saving & Environmentally Friendly
High-precision Temperature Control & Safe Storage
The high-precision microcomputer temperature control system and platinum resistor temperature sensors can realize more precise temperature control and enable users to set temperature inside the cabinet within a range from -40 to -86℃.
Well-developed Audible & Visual Alarm System
Multiple alarm functions, such as high temperature/low temperature alarm, power failure alarm, abnormal voltage alarm, sensor failure alarm, low battery alarm, alarm of poor heat dissipation of condenser and system failure alarm, can improve safety of storage.
Refrigeration System
Environmentally-friendly Freon-free refrigerant and high-effiffifficiency compressor supplied by an international famous brand ensure energy saving and high effiffifficiency; The CFC-free Polyurethane foaming technology, the super-thick thermal insulation layer and VIP:Vacuum Insulation Panel can improve effffect of thermal insulation to a large extent.
Model | GUL-86C135 | GUL-86C320 | GUL-86C600 |
Cabinet Type | Chest | Chest | Chest |
Capacity(L) | 135 | 320 | 600 |
Internal Size(W*D*H)mm | 490*470*580 | 1200*470*570 | 1200*815*610 |
External Size(W*D*H)mm | 1320*890*1030 | 2030*890*1020 | 2033*1190*1037 |
Package Size(W*D*H)mm | 1470*990*1241 | 2193*1003*1256 | 2145*1305*1234 |
NW/GW(Kgs) | 200/231 | 280/328 | 352/398 |
Performance | |||
Temperature Range | -40~-86℃ | -40~-86℃ | -40~-86℃ |
Ambient Temperature | 16-32℃ | 16-32℃ | 16-32℃ |
Cooling Performance | -86℃ | -86℃ | -86℃ |
Climate Class | N | N | N |
Controller | Microprocessor | Microprocessor | Microprocessor |
Display | Digital display | Digital display | Digital display |
Refrigeration | |||
Compressor | 1pc | 1pc | 2pcs |
Cooling Method | Direct cooling | Direct cooling | Direct cooling |
Defrost Mode | Manual | Manual | Manual |
Refrigerant | Mixture gas | Mixture gas | Mixture gas |
Insulation Thickness(mm) | 152 | 152 | 130 |
Construction | |||
External Material | Steel plates with spraying | Steel plates with spraying | Steel plates with spraying |
Inner Material | Stainless steel | Stainless steel | Stainless steel |
External Door | 1(Steel plates with spraying) | 1(Steel plates with spraying) | 1(Steel plates with spraying) |
Door Lock with Key | Yes | Yes | Yes |
Foaming Lid | 2 | 3 | 3 |
Access Port | 1pc. Ø 40 mm | 1pc. Ø 40 mm | 1pc. Ø 40 mm |
Casters | 4 | 6 | 6 |
Data Logging/Interval/ Recording Time | USB/Record every 10 minute / 2 years | ||
Backup Battery | Yes | Yes | Yes |
Alarm | |||
Temperature | High/Low temperature,High ambient temperature | ||
Electrical | Power failure , Low battery | ||
System | Sensor failure, Condenser overheating alarm, built-in datalogger USB failure, Main board communication error | ||
Electrical | |||
Power Supply(V/HZ) | 220-240~/50 | 220-240~/50 | 220-240~/50 |
Rated Current(A) | 5.78 | 5.6 | 9.5 |
Accessories | |||
Standard | Remote alarm contact,RS485 | ||
Options | Chart recorder, CO2 backup system, Printer |